
MAF CAL Advance – Lambda Target Tuning
October 5, 2026This article goes through the process of adjusting engine fuelling/changing engine lambda target using MAF CAL Advance
Before starting the process, there are some assumptions that need to be made.
Assumptions
1.It is assumed the engine has a good tune. And MAF CAL Advance is being used to tweak fuelling.
2.It is also assumed the engine ECU is running open loop fuel control. MAF CAL Advance adjustments will be cancelled out by engine ECU if engine ECU is operating with closed loop fuelling.
3.MAF CAL Advance has been installed & setup correctly ie values shown in diagnostic function of MAF CAL Advance app are correct
4.We are using the closed loop function and load enrichment function
5.Engine is up to operating temperature.
The Process – Closed Loop Active
Step 1 – Targets
In the MAF CAL Advance app we enter our load thresholds (min and max) and we enter our lambda targets.
We also enter our MAP at idle. Set this to a value the engine will never normally reach when idling. Get this as close to the idle limit as possible. We do not want closed loop function operating when we have lifted the throttle and clutch is still engaged ie coasting.


Step 2 – Adjustments
If we have a rough idea of how much fuel we need to add, we make the adjustments in the MAF CAL Advance app now, eg we know we want to add about 4% more fuel at idle, add +4% adjustment to the relevant MAF signal voltages.
Step 3 – Gather Data
With MAF CAL Advance on, Turn off Closed Loop function and turn back on in the app. This resets the timer and activates closed loop control immediately (instead of MAF CAL Advance waiting for engine warm up period of 3 minutes).
We drive the vehicle/run it on a dyno at steady low/medium loads and low/medium RPM.
Important – Constantly monitor AFRs when using MAF CAL Advance
Closed Loop Activate Conditions
Load must be withing 15kPa for at least 2.5 seconds (closed loop activation timer) for closed loop function to activate. Adjustments are made every 1.5 seconds. If load moves more than 15kPa closed loop activation timer resets.
Also, the maximum adjustment closed loop will make is +/- 3% for min load and +/-4% for max load.
Step 4 – Analyse Data
After testing and before turning MAF CAL Advance off, we go to the app and we select the voltage blocks at top of the screen which represent MAF signal. This will populate 5 lines of numbers. The top 2 are the stored values, the bottom three are the closed loop values. Using the data here we change our stored values to that of the closed loop values.

For Example.
Before testing, for “MAF In Volt” 3.5, we have a “stored multiplier” of 1.03 and a “stored multiplier load” value of 1.03.
After testing, 3.5 volts has a “closed loop multiplier” of 1.05 and a “closed loop multiplier load” of 1.05, we would adjust the stored numbers to match the closed loop numbers. We repeat this process for every MAF In voltage step (where the Closed Loop function has made adjustments). All the time we monitor our AFRs to confirm adjustments are correct/not going too far.
Repeat
With the numbers stored we turn off the Closed Loop function and turn it back on. This will reset the closed loop numbers.
Now we return to Step 3 and keep repeating the process until we are getting closed loop values that are within 0.02 to 0.03 of the stored values.
As we close in on our desired AFRs, we can start to put more RPM and load (flow) into the engine.
Tip – It is better to start with low loads (below min load threshold) and to get “Stored Mult” multipliers in the ball park before moving on the “Stored Mult Load” adjustments. Stored Mult Load number are based on the Stored Mult number eg formula is Maf In Volt * Stored Mult * Stored Mult Load = MAF Out Volt
Alternative Method – Closed Loop Function Off/External Datalogger Method
The process with the Closed Loop off, is more or less the same.
Instead of looking at the closed loop adjustments in the app, we look at the logs from an external datalogger.
To analyse the logs, setup the table to have MAF In Voltage on one axis and load on the other. And lambda to be the data shown in the cell.

Start with cells which are below the “Min Load” threshold.
See which MAF In voltages are not giving the desired lambda (AFR) and make the required adjustments in the MAF CAL Advance app.
With the load load MAF adjustments in the ball park start exploring loads above “Max Load Enrich” threshold to populate the “Stored Mult Load” values.
Do not look at lambda values/cells which lie between “Min Load Enrich” and “Max Load Enrich Thresholds”, until you have “Stored Mult” and “Stored Mult Load” multipliers in the ballpark. When these numbers are in the ballpark you should see, in the logs, the gradual transition in the lambda values from your “Lambda Target Idle” number up to the “Lambda Target Rich” values when engine load is between these thresholds.
Do not make adjustments to the multipliers based on AFR/Lambda numbers which are between the load thresholds.
Example Datalog Analysis

For the 0.5BAR row and below ,we are looking to get all cells being close to 13AFR.
For the 0BAR row and above we are looking to get all cells close to 14.7.
We need to use some common sense here. Values below -0.750 BAR and above 2 volts will be off the accelerator so lambda readings irrelevant. Also we have a value of 11.70 but its only one data point (number in brackets) so we’ll ignore it. Idle vacuum is around 0.65 BAR.
If we are targeting 14.7AFR we can add some fuel (eg increase “Stored Mult”) at 2, 2.5 and 3 volts.
Below red line we have cells targeting “Max Load Enrich” lambda target. If we are targeting 13 AFR we can say to add fuel at 3.5 and 4 volts (eg increase “Stored Mult Load” multiplier).
After Adjustments

With the new settings, we are very close to what we want. “Lambda Target Idle” close to 14.7. Perhaps we can remove an extra 1% (0.01) of multiplier to the 2.5 and 3 volt cells in the app.
For “Load Mult” perhaps we could add a percentage to 3.5 and 3 volts.
The transition load ie 0 BAR to 0.5 BAR we can see the AFR getting richer.
Fuel Tuning – Questions
And that is the tuning process with the MAF CAL Advance. If you have any questions about this article or product, leave a comment below or send us an email

